The structure of the enclosed linear scale is standard grating feet shell that is suitable for high vibration frequency and the maximum measured length of 1000 mm, compact and grating ruler shell is suitable for the installation of the small space, the maximum measured length is 600 mm, and the thickened linear scale length can reach 3000 mm.

model:
Quantity:
  • MSC5/1
  • FEMA
  • Linear Scale
  • 20μm
  • 50~3000mm
1.Application of Thickened Linear Scale
Enclosed linear scale can effectively prevent dust, the chip and the splash of cutting fluid, is the ideal choice for machine tools. Aluminum casing and seal soft article can protect the linear scale, the scanning unit and orbit ; it also can protect from the influence of dust, chip, and cutting fluid. Built-in scanning unit friction force is little, installed in the motion of orbit on the linear scale. It is connected with the installation of external frame through a connecting shaft, which can compensate the linear scale and machine for positive error which is inevitable between the tracks. The structure of the enclosed linear scale is standard grating feet shell that is suitable for high vibration frequency and the maximum measured length of 1000 mm, compact and grating ruler shell is suitable for the installation of the small space, the maximum measured length is 600 mm, and the thickened linear scale length can reach 3000 mm. 
Maximum effective length is 3000 mm or less, universal products, widely used in apparatus, machine tool, PLC control, and other fields.
 
2. Installation Size
0
3. MSC Technical Specifications
 
Product Name Thickened Linear Scale MSC Series
Model MSC5 MSC1
Resolution 5μm 1μm
Max. Working Speed 60m/min 20m/min
Grating Pitch 20μm
Output Signal TTL,RS422
Grating Measuring System Transmission infrared optical measurement system, infrared wavelength:880(um)
Measuring Length 50~3000mm
Scan Unit Rolling System 45° five ball bearing rolling system
Working Voltage 5V±5%DC
Working Enviroment Temperature :-1045°C; Humidity:≤90%
Accuracy 1010≤ML≤2000mm: Standard:±30μm ; Precision:±20μm
2100≤ML≤30000mm:Standard:±50μm ; Precision: ±24μm
 
 
4 Technical Specifications
Model Resolution Measuring Length Max. Working Speed Accuracy
1010-500mm 2100-1000mm
Standard Precision Standard Precision
MSC5 5um 50-3000mm 60m/min ±30um ±20um ±50um ±24um
MSB1 1um 50-3000mm 20m/min ±30um ±20um ±50um ±24um
 